Model
|
T-120D |
| CH1 |
CH2 |
CH3 |
| DC output voltage, current |
5V 2-12A |
12V 0.2~0.5A |
12V 0.2~2A |
| Wave and noise |
80mVp-p |
120mVp-p |
180mVp-p |
| Inlet wire stability |
±0.5% |
±1% |
±1% |
| Load stability |
±0.5% |
±5% |
±5% |
| Efficiency |
80% |
| Adjustable range for DC voltage |
CH1:±10% |
CH1:±5% |
CH1:±5% |
| Input voltage range |
90~ 132VAC/180~ 264VAC by switch 254 ~ 370VDC 47 ~ 63Hz |
| Impact current |
Cold start current 30A/1 15VAC 60A/230VAC |
| Overload protection |
105% ~ 150% cut off the output, automatic recovery |
| Over voltage protection |
CH1:115~ 135% shut down O/P voltage, re-power on to recover |
| Setup, rise, hold up time |
200ms, 50ms, 16ms/230VAC at full load |
| Withstand voltage |
I/P- -O/P: 1.5kV I/P. -FG:1 .5kV O/P-FG: 0.5kV 1minute |
| Isolation resistance |
I/P- -O/P I/P- -FG O/P- FG: 500VDC/100MQ |
| Working temperature |
-10°C~ +50°C |
| Overall dimension(mm) |
 |